Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
Chinese Journal of Contemporary Pediatrics ; (12): 502-507, 2023.
Article in Chinese | WPRIM | ID: wpr-981985

ABSTRACT

OBJECTIVES@#To evaluate the clinical effectiveness of integrated management during the perinatal period for fetuses diagnosed with total anomalous pulmonary venous connection (TAPVC) by prenatal echocardiography.@*METHODS@#Clinical data of 64 cases of TAPVC fetuses diagnosed by prenatal echocardiography and managed with integrated perinatal care in Qingdao Women and Children's Hospital from January 2017 to December 2021 were retrospectively analyzed. Integrated perinatal care included multidisciplinary collaboration among obstetrics, fetal medicine, ultrasound, pediatric cardiology, pediatric anesthesia, and neonatology.@*RESULTS@#Among the 64 TAPVC fetuses, there were 29 cases of supracardiac type, 27 cases of intracardiac type, 2 cases of infracardiac type, and 6 cases of mixed type. Chromosomal analysis was performed in 42 cases, and no obvious abnormalities were found. Among the 64 TAPVC fetuses, 37 were induced labor, and 27 were followed up until term birth. Among the 27 TAPVC cases, 2 cases accepted palliative care, 2 cases were referred to another hospital for treatment and lost to follow-up, while the remaining 23 cases underwent primary repair surgery. One case died within 6 months after the operation due to low cardiac output syndrome, while the other 22 cases were followed up for (2.1±0.3) years with good outcomes (2 cases underwent a second surgery within 1 year after the first operation due to anastomotic stenosis or pulmonary vein stenosis).@*CONCLUSIONS@#TAPVC fetuses can achieve good outcomes with integrated management during the perinatal period.


Subject(s)
Female , Humans , Pregnancy , Infant, Newborn , Echocardiography , Heart Defects, Congenital/surgery , Pulmonary Veins/surgery , Retrospective Studies , Scimitar Syndrome/surgery
2.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

ABSTRACT

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Subject(s)
Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/physiopathology , Recurrence , Atrial Fibrillation/physiopathology
3.
Arq. bras. cardiol ; 117(1): 100-105, July. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1285226

ABSTRACT

Resumo Fundamento Na fibrilação atrial paroxística (FAP), o isolamento das veias pulmonares com criobalão (IVP-CB) tem eficácia semelhante à da ablação por radiofrequência (IVP-RF). Em procedimentos de reablação após IVP-RF, a reconexão das VPs é alta, ao passo que em pacientes com reablação após IVP-CB, as informações são escassas. Objetivo Determinar os locais de reconexão das VPs em pacientes que foram submetidos à reablação após IVP-CB inicial. Métodos Pacientes que foram submetidos a um procedimento de reablação de fibrilação atrial, após um IVP-CB inicial para FAP foram incluídos. O mapeamento eletroanatômico do AE foi utilizado. Um local de reconexão foi definido com a presença de uma voltagem de 0,3mV ou maior nas VPs e condução unidirecional ou bidirecional nas VPs durante o ritmo sinusal. Os locais de reconexão foram identificados por meio de corte paraesternal longitudinal e posteriormente ablacionados com radiofrequência. Resultados Dos 165 pacientes submetidos ao IVP inicial, 27 necessitaram reablações, dos quais 18 (66,6%) eram do sexo masculino, com média de idade de 55+12,3 anos. O tempo de recorrência foi de 8,9+6,4 meses. A reconexão das VPs foi encontrada em 21 (77,8%) pacientes. Houve um total de 132 lacunas de condução, seis por paciente, 3,6 por VP. Um número significativo de lacunas ocorreu na região ântero-superior da VP superior esquerda (VPSE) e nas regiões septal e inferior da VP superior direita (VPSD). Conclusões As VPs superiores apresentaram os locais de maior reconexão, principalmente na região anterior da VPSE e na região septal da VPSD. A razão por trás disso pode ser devido à maior espessura da parede atrial e à dificuldade em alcançar o contato de criobalão adequado.


Abstract Background In paroxysmal atrial fibrillation (PAF), pulmonary vein isolation using cryoballoon (CB-PVI) has similar efficacy as radiofrequency ablation (RF-PVI) has. In redo ablation procedures following RF-PVI, PV reconnection is high, whereas in patients with redo following CB-PVI, information is scarce. Objective To determine the sites of PV reconnection in patients who underwent redo ablation after initial CB-PVI. Methods Patients who underwent an AF redo procedure, following an initial CB-PVI for PAF were included. LA electroanatomic mapping was used. A reconnection site was defined as the presence of a voltage of 0.3mV or greater in the PV and unidirectional or bidirectional conduction in the PV during sinus rhythm. Reconnections sites were identified using a clock-face view description and were ablated with radiofrequency afterwards. Results Out of the 165 patients who underwent initial PVI, 27 required redo ablations, of which 18 (66.6%) were males, with a mean age of 55+12.3 years. The time of recurrence was 8.9+6.4 months. PV reconnection was found in 21 (77.8%) patients. There was a total of 132 conduction gaps, six per patient, 3.6 per PV. A significant number of gaps were in the anterosuperior region of the left superior PV (LSPV), and in the septal and inferior regions of the right superior PV (RSPV). Conclusions The upper PVs had the most reconnection sites, mostly at the anterior region of the LSPV and the septal region of the RSPV. The reason behind this may be due to greater atrial wall thickness, and difficulty in achieving adequate cryoballoon contact.


Subject(s)
Humans , Male , Adult , Aged , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Recurrence , Treatment Outcome , Middle Aged
5.
Medicina (B.Aires) ; 81(2): 282-285, June 2021. graf
Article in English | LILACS | ID: biblio-1287281

ABSTRACT

Abstract Total anomalous pulmonary venous drainage is a rare and diverse anomaly, accounting for 1% to 3% of patients with congenital heart disease. Newborns with diagnosis of an obstructed total anomalous pulmonary venous dainage are extremely ill soon after birth and often present with severe cyanosis, pulmonary hypertension and low cardiac output requiring urgent surgical intervention. Transcatheter palliative stenting of the obstructive vertical vein can be an acceptable alternative as a bailout intervention before complete surgical correction is undertaken. This report of two cases highlights the feasibility, safety and effectiveness of the inter ventional palliative procedure and confirms that this technique can be an acceptable and attractive bridge in the algorithm of medical decisions during the evaluation of these critical patients.


Resumen El drenaje venoso pulmonar anómalo total es una enfermedad poco frecuente y de presentación diversa y se observa en el 1% a 3% de las cardiopatías congénitas. Si se asocia a obstrucción, se convierte en una afección grave en el recién nacido, mostrando cianosis intensa, hipertensión arterial pulmonar y bajo gasto cardíaco con indicación de intervención quirúrgica de urgencia. El implante de stent por cateterismo de forma paliativa para aliviar la obstrucción puede ser una alternativa aceptable de tratamiento como intervención de rescate antes de la corrección quirúrgica definitiva. Presentamos dos casos de intervención percutánea paliativa mostrando que esta técnica puede ser eficaz como puente al tratamiento quirúrgico definitivo para ser incorporado en la toma de decisiones de estos pacientes críticos.


Subject(s)
Humans , Infant, Newborn , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Heart Defects, Congenital , Hypertension, Pulmonary , Stents , Drainage
6.
Rev. bras. cir. cardiovasc ; 36(1): 133-136, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1155803

ABSTRACT

Abstract Infantile scimitar syndrome (SS) is a rare congenital heart disease and has high mortality. Guidelines have not been established, but surgery is indicated in symptomatic patients. Despite the various surgical approaches, outcomes continue to be disappointing. We present our surgical experience with an infantile SS patient who had stenotic pulmonary veins contralateral to the hypoplastic lung with complicated anatomy. There are few cases with this complex pathology in the literature. Moreover, our patient was the first transplant-free survivor with this complexity in the literature.


Subject(s)
Humans , Infant , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Scimitar Syndrome/surgery , Scimitar Syndrome/complications , Scimitar Syndrome/diagnostic imaging , Heart Defects, Congenital , Constriction, Pathologic , Stenosis, Pulmonary Vein/surgery , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/diagnostic imaging
7.
Arq. bras. cardiol ; 116(2): 334-343, fev. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1153006

ABSTRACT

Resumo Após mais de 20 anos desde sua utilização inicial, a ablação por cateter se tornou um procedimento rotineiramente realizado para tratamento de pacientes com fibrilação atrial (FA). Fundamentado inicialmente no isolamento elétrico das veias pulmonares em pacientes com FA paroxística, subsequentes avanços no entendimento da fisiopatologia levaram a técnicas adicionais não só para obter melhores resultados, mas também para tratar pacientes com formas persistentes de arritmia, assim como pacientes com cardiopatia estrutural e insuficiência cardíaca.


Abstract More than 20 years since its initial use, catheter ablation has become a routinely performed procedure for the treatment of patients with atrial fibrillation (AF). Initially based on the electrical isolation of pulmonary veins in patients with paroxysmal AF, subsequent advances in the understanding of pathophysiology led to additional techniques not only to achieve better results, but also to treat patients with persistent forms of arrhythmia, as well as patients with structural heart disease and heart failure.


Subject(s)
Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Recurrence , Treatment Outcome
8.
Chinese Journal of Medical Instrumentation ; (6): 517-523, 2021.
Article in Chinese | WPRIM | ID: wpr-922050

ABSTRACT

Pulsed electric field(PEF) provides high-energy instantaneous pulse and release energy to myocardial cell membrane, resulting in irreversible electroporation and causes myocardial cell contents leakage, destruction of intracellular homeostasis, cell death, and slight inflammatory response. PEF as non-thermal energy promotes the design and application of arrhythmia ablation catheter to enter a new stage. There are currently limited clinical studies that have proved the safety and effectieness of Farawave PEF catheter, PVAC GOLD PEF catheter, Lattice-tip Sphere-9 PEF and radiofrequency (RF) catheter used for atrial fibrillation ablation, but still need further discussion. The research of atrial fibrillation ablation with PEF is under study in China. In this paper, the design and application of PEF ablation for tachyarrhythmia are reviewed.


Subject(s)
Humans , Atrial Fibrillation/surgery , Catheter Ablation , Catheters , Pulmonary Veins/surgery , Tachycardia
9.
Arq. bras. cardiol ; 115(3): 528-535, out. 2020. tab, graf
Article in Portuguese | LILACS, SES-SP | ID: biblio-1131326

ABSTRACT

Resumo Fundamento O isolamento elétrico das veias pulmonares é reconhecidamente base fundamental para o tratamento não farmacológico da fibrilação atrial (FA) e, portanto, tem sido recomendado como passo inicial na ablação de FA em todas as diretrizes. A técnica com balão de crioenergia, embora amplamente utilizada na América do Norte e Europa, ainda se encontra em fase inicial em muitos países em desenvolvimento, como o Brasil. Objetivo Avaliar o sucesso e a segurança da técnica de crioablação em nosso serviço, em pacientes com FA paroxística e persistente. Métodos Cento e oito pacientes consecutivos com FA sintomática e refratária ao tratamento farmacológico foram submetidos à crioablação para isolamento das veias pulmonares. Os pacientes foram separados em dois grupos, de acordo com a classificação convencional da FA paroxística (duração de até sete dias) e persistente (FA por mais de sete dias). Dados de recorrência e segurança do procedimento foram analisados respectivamente como desfechos primário e secundário. O nível de significância adotado foi de 5%. Resultados Cento e oito pacientes, com idade média de 58±13 anos, 84 do sexo masculino (77,8%), foram submetidos ao procedimento de crioablação de FA. Sessenta e cinco pacientes apresentavam FA paroxística (60,2%) e 43, FA persistente (39,2%). O tempo médio do procedimento foi de 96,5±29,3 minutos e o tempo médio de fluoroscopia foi de 29,6±11,1 minutos. Foram observadas cinco (4,6%) complicações, nenhuma fatal. Considerando a evolução após os 3 meses iniciais, foram observadas 21 recorrências (19,4%) em período de um ano de seguimento. As taxas de sobrevivência livre de recorrência nos grupos paroxístico e persistente foram de 89,2% e 67,4%, respectivamente. Conclusão A crioablação para isolamento elétrico das veias pulmonares é um método seguro e eficaz para tratamento da FA. Nossos resultados estão consoantes com demais estudos, que sugerem que a tecnologia pode ser utilizada como abordagem inicial, mesmo nos casos de FA persistente. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Electrical isolation of the pulmonary veins is recognized as the cornerstone of non-pharmacological treatment of Atrial Fibrillation (AF), and therefore, has been recommended as the first step in AF ablation according to all guidelines. Even though the cryoballoon technology is widely used in North America and Europe, this experience is still incipient in many developing countries such as Brazil. Objective To evaluate initial results regarding success and safety of the new technology in patients with persistent and paroxysmal AF. Methods One hundred and eight consecutive patients with symptomatic AF refractory to pharmacological treatment were submitted to cryoablation for isolation of the pulmonary veins. Patients were separated into two groups according to AF classification: persistent (AF for over one week); or paroxysmal (shorter episodes). Recurrence and procedural safety data were analyzed respectively as primary and secondary outcomes. The level of significance was 5%. Results One hundred and eight patients, with mean age 58±13 years, 84 males (77.8%), underwent cryoablation. Sixty-five patients had paroxysmal AF (60.2%) and 43 had persistent AF (39.2%). The mean time of the procedure was 96.5±29.3 minutes and the mean fluoroscopy time was 29.6±11.1 minutes. Five (4.6%) complications were observed, none fatal. Considering a blanking period of 3 months, 21 recurrences (19.4%) were observed in a one-year follow-up period. The recurrence-free survival rates of AF in the paroxysmal and persistent groups were 89.2% and 67.4%, respectively. Conclusion Cryoablation for electrical isolation of the pulmonary veins is a safe and effective method for the treatment of AF. Our results are consistent with other studies suggesting that this technology can be used as an initial technique even in cases of persistent AF.


Subject(s)
Humans , Male , Aged , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Recurrence , Brazil , Treatment Outcome , Middle Aged
10.
Rev. bras. cir. cardiovasc ; 35(5): 841-843, Sept.-Oct. 2020. tab, graf
Article in English | SES-SP, LILACS | ID: biblio-1137322

ABSTRACT

Abstract Cardiac rhythm disorders are common in many patients with cancer. The management of synchronous long-standing persistent atrial fibrillation and pulmonary lesions remains a serious surgical dilemma due to the lack of clinical data and surgical guidelines. To the best of our knowledge, this is the first described case of simultaneous thoracoscopic pulmonary segmentectomy and left atrial posterior wall and pulmonary vein isolation combined with left atrial appendage resection in a patient with early-stage primary lung cancer and long-standing persistent atrial fibrillation.


Subject(s)
Humans , Female , Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Catheter Ablation/methods , Adenocarcinoma, Mucinous/surgery , Adenocarcinoma, Mucinous/complications , Adenocarcinoma, Mucinous/diagnostic imaging , Pneumonectomy/methods , Pulmonary Veins/surgery , Thoracoscopy , Tomography, X-Ray Computed , Treatment Outcome , Atrial Appendage/surgery , Heart Atria/surgery , Lung Neoplasms/surgery , Lung Neoplasms/complications , Lung Neoplasms/diagnostic imaging
11.
Clinics ; 75: e1672, 2020. tab, graf
Article in English | LILACS | ID: biblio-1133481

ABSTRACT

OBJECTIVE: To evaluate whether thawing rate could be a novel predictor of acute pulmonary vein isolation (PVI) and explore the predictive value of thawing rate as a factor ensuring long-term PVI (vagus reflex). METHODS: A total of 151 patients who underwent cryoballoon ablation for atrial fibrillation (AF) were enrolled in this retrospective study between January 2017 and June 2018. The thawing rate was calculated using the thawing phase of the cryoablation curve. Receiver operating characteristic (ROC) curve was used to analyze the predictive value of the thawing rate for acute PVI and vagus reflex. RESULTS: ROC curve analyses revealed that the interval thawing rate at 15°C (ITR15) was the most valuable predictor of PVI, with the highest area under curve (AUC) value of the ROC curve. The best cut-off value of ITR15 for PVI was ≤2.14°C/S and its sensitivity and specificity were 88.62% and 67.18%, respectively. In addition, the ITR15 of the successful PVI group after cryoballoon ablation was significantly slower than the failed PVI group. ITR15 was a predictor of vagus reflex and the occurrence of vagus reflex group had a slower ITR15 compared to the non-occurrence group. CONCLUSIONS: Thawing rate was a novel predictor of acute PVI and the ITR15 was the most valuable predictor of acute PVI. In addition, ITR15 was a predictive factor ensuring long-term PVI (vagus reflex). Our study showed that thawing rate may serve in the early identification of useless cryoballoon ablation.


Subject(s)
Humans , Male , Female , Pulmonary Veins/surgery , Recurrence , Atrial Fibrillation , Stroke Volume , Retrospective Studies , Ventricular Function, Left , Treatment Outcome , Catheter Ablation
12.
Rev. bras. cir. cardiovasc ; 34(6): 765-768, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057488

ABSTRACT

Abstract Clinical data: Infant, 7 months, female, referred to our department at one month of age, suspecting of congenital heart disease for further investigation. Chest radiography: Demonstrates cardiomegaly and prominent pulmonary vascular markings. Electrocardiography: Shows right ventricular hypertrophy and left anterior fascicular block. Echocardiography: Evidenced common atrioventricular valve with two orifices and the left superior pulmonary vein draining on the brachiocephalic vein. Computed tomography angiography: This complementary imaging exam was performed to confirm the diagnosis. Diagnosis: The patient presented an association between AVSD and PAPVC, a rare combination. The clinical picture of heart failure was preponderant, characterized by need for diuretics and complementary exams findings, and early surgical treatment was indicated. Operation: The operation was performed through a median sternotomy with 123 minutes of cardiopulmonary bypass and 89 minutes of cross-clamping time. The patient had no postoperative complications, remaining 10 days hospitalized.


Subject(s)
Humans , Female , Infant , Abnormalities, Multiple/diagnostic imaging , Vascular Malformations/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Septal Defects, Atrial/diagnostic imaging , Pulmonary Veins/abnormalities , Pulmonary Veins/surgery , Abnormalities, Multiple/surgery , Cardiopulmonary Bypass , Electrocardiography , Vascular Malformations/surgery , Computed Tomography Angiography , Heart Defects, Congenital/surgery , Heart Septal Defects, Atrial/surgery
17.
Hosp. Aeronáut. Cent ; 9(2): 102-4, 2014. ilus
Article in Spanish | LILACS | ID: lil-776837

ABSTRACT

El síndrome de vena cava superior, se corresponde a la obstrucción de la misma, siendo su causa más frecuente la etiología neoplásica. Objetivos: Se realiza el análisis y la presentación del siguientecaso clínico con el objetivo de considerar la utilidad de laendoprótesis. Caso Clínico: Paciente de 61 años, masculino que ingresa porsíndrome de vena cava superior. Se le realiza Tac Torácica con presencia de tumor hiliar derecho en ubicación retrocavopretraqueal que estenosa a la vena cava superior. Con mala evolución del cuadro se decide colocación de endoprotesis vascular. Aliviando la sintomatología para luego realiza eldiagnostico. Discusión: dado que el tratamiento de esta entidad es tratar lacausa de la obstrucción, se debe tener en cuenta la repercusión que genera, llevando inclusive a la muerte del paciente. Por lo que es de utilidad resolver la dificultad con la colocación de una endoprotesis, para luego estudiar y diagnosticar la etiología y asícondicionar un tratamiento adecuado...


The superior vena cava syndrome, corresponds to the obstruction of the superior vena cava, and its most common cause neoplastic etiology. Objectives: Analysis and presentation of the following case inorder to consider the usefulness of the endoprosthesis is made. Case presentation: A 61 year old male was admitted with superior vena cava syndrome. He takes Tac Thoracic presence of right hilar tumor location retrocavopretraqueal stenosing thesuperior vena cava. With bad symptom onset vascular endoprosthesis placement is decided. Relieving the symptoms and then performs the diagnosis. Discussion: Because the treatment of this entity is to treat thecause of the obstruction, must take into account the impact it creates, even leading to death. It is useful to solve the difficulties with the placement of a stent, and then study and diagnose theetiology and thus an appropriate treatment...


Subject(s)
Humans , Male , Adult , Superior Vena Cava Syndrome/therapy , Pulmonary Veins/abnormalities , Pulmonary Veins/surgery , Vena Cava, Superior/pathology , Venae Cavae/pathology
18.
Arq. bras. cardiol ; 101(6): 519-527, dez. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-701268

ABSTRACT

FUNDAMENTO: Índices de ondas P são marcadores interessantes para prever recorrências de fibrilação atrial (FA) pós ablação. OBJETIVO: Esse estudo avalia o valor dos índices de onda P para prever recorrências após isolamento da veia pulmonar (IVP) em pacientes com fibrilação atrial paroxística. MÉTODOS: Foram selecionados 198 pacientes (57 ± 8 anos, 150 homens) com FA paroxística sintomática refratária a medicamentos submetidos ao IVP em nosso hospital. Um eletrocardiograma de 12 derivações foi utilizado para medir a duração da onda P na derivação II, a força terminal de P (FTP) na derivação V1, o eixo e a dispersão da onda P. RESULTADOS: No acompanhamento de 9 ± 3 meses, as recorrências ocorreram em 60 (30,3%) pacientes. Os pacientes que apresentaram recorrência de FA tiveram maior duração média de onda P (122,9 ± 10,3 versus 104,3 ± 14,2 ms, p < 0,001), maior dispersão da onda P (40,7 ± 1,7 ms vs 36,6 ± 3,2 ms, p < 0,001). A duração da onda P > 125 ms apresenta 60% de sensibilidade, especificidade de 90%, valor preditivo positivo (VPP) de 72% e valor preditivo negativo (VPN) de 83,7%, enquanto a dispersão da onda P > 40 ms tem 78% de sensibilidade, 67% de especificidade, PPV 51% e VPN de 87,6%. 48/66 (72,7%) dos pacientes com FTP < -0,04 mm/segundo vs 12/132 (9%) com FTP > -0,04 mm/segundo tiveram recorrência de FA (p < 0,001). O eixo da onda P não diferiu entre os dois grupos. Na análise multivariada, os índices da onda P não foram independentes do tamanho do átrio esquerdo e da idade. CONCLUSÕES: A duração da onda P > 125 ms, a dispersão da onda P > 40 ms e FTP em V1 < -0,04 mm/sec são bons preditores clínicos das recorrências de FA pós IVP em pacientes com fibrilação atrial paroxística; contudo, eles não foram independentes do tamanho do átrio esquerdo e da idade.


BACKGROUND: P-wave indices are appealing markers for predicting atrial fibrillation (AF) recurrences post ablation. OBJECTIVE: This study evaluates the value of P wave indices to predict recurrences post pulmonary vein isolation (PVI) in patients with paroxysmal AF. METHODS: We selected 198 patients (57 ± 8 years, 150 males) with symptomatic drug-refractory paroxysmal AF undergoing PVI in our hospital. A 12-lead electrocardiogram was used to measure P wave duration in lead II, P wave terminal force (PWTF) in lead V1, P wave axis and dispersion. RESULTS: During a follow-up of 9 ± 3 months, recurrences occurred in 60 (30.3%) patients. The patients that had AF recurrence had longer mean P wave duration (122.9 ± 10.3 vs 104.3 ± 14.2 ms, p < 0.001), larger P wave dispersion (40.7 ± 1.7 ms vs 36.6 ± 3.2 ms, p < 0.001). P wave duration > 125 ms has 60% sensitivity, 90% specificity, positive predictive value (PPV) of 72% and negative predictive value (NPV) of 83.7%, whereas P wave dispersion > 40 ms has 78% sensitivity, 67% specificity, PPV of 51% and NPV of 87.6% 48/66 (72.7%) patients with PWTF < -0.04 mm/second vs12/132(9%) with PWTF > -0.04 mm/second showed recurrence of AF (p < 0.001). P wave axis was not different between two groups. On multivariate analysis, P wave indices were not independent from left atrial size and age. CONCLUSIONS: P wave duration > 125 ms, P wave dispersion > 40 ms and PWTF in V1 < -0.04 mm/sec are good clinical predictors of AF recurrences post PVI in patients with paroxysmal atrial fibrillation; however they were not independent from left atrial size and age.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Electrocardiography/standards , Heart Atria/physiopathology , Pulmonary Veins/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Biomarkers/analysis , Catheter Ablation/methods , Heart Atria/surgery , Predictive Value of Tests , Pulmonary Veins/physiopathology , Recurrence , Sensitivity and Specificity
19.
Rev. bras. cardiol. invasiva ; 21(4): 384-389, out.-dez. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-703692

ABSTRACT

INTRODUÇÃO: Os autores relatam a experiência inicial da oclusão da comunicação interatrial ostium secundum (CIA) com a utilização da prótese Memopart® (Shanghai Shape Memory Alloy Co Ltd, Shanghai, China). MÉTODOS: Estudo prospectivo observacional, no qual uma série de pacientes portadores de defeitos com significativa repercussão hemodinâmica e características anatômicas favoráveis ao implante foi submetida à oclusão percutânea de CIA. O procedimento foi realizado por via femoral percutânea, pela técnica habitual. O período de seguimento foi de 10,3 ± 5 meses, com controles clínicos e ecocardiográficos 24 horas (ou antes da alta hospitalar), 1, 3, 6 e 12 meses após o implante. RESULTADOS: No período de fevereiro de 2012 a abril de 2013, foram submetidos à oclusão percutânea de CIA 21 pacientes, sendo 16 do sexo feminino, com idade média de 33,1 ± 18,7 anos. O diâmetro médio do defeito foi de 19,04 ± 6,25 mm e o tamanho da prótese foi de 21,42 ± 6,73 mm (8 a 34 mm). O implante foi realizado com êxito em todos os casos, verificando-se oclusão total no controle antes da alta hospitalar. No seguimento, todos os pacientes estiveram assintomáticos e comprovou-se a persistência da oclusão total do defeito. Não houve mortalidade e nem outras complicações na série. CONCLUSÕES: A oclusão percutânea da CIA utilizando-se prótese Memopart® é um procedimento eficaz e seguro, dentro dos limites desta investigação. O implante da prótese é simples e apresenta alto índice de oclusão imediata, inclusive de defeitos de grandes dimensões.


BACKGROUND: The authors report their initial experience with the Memopart™ device (Shanghai Shape Memory Alloy Co Ltd, Shanghai, China) for the occlusion of secundum atrial septal defect (ASD). METHODS: This was a prospective observational study of a series of patients undergoing percutaneous occlusion of ASD with right ventricle volume overload and favorable anatomic characteristics. The procedure was performed by percutaneous femoral approach. The mean follow-up was 10.3 ± 5 months, with clinical and 24-hour echocardiographic evaluations (or before hospital discharge), 1, 3, 6, and 12 months after implantation. RESULTS: From February/2012 to April/2013, 21 patients, 16 females, mean age 33.1 ± 18.7 years, were submitted to percutaneous occlusion of an ASD. The average diameter of the defect was 19.04 ± 6.25 mm and the device size was 21.42 ± 6.73 mm (8 to 34 mm). Total occlusion of the defect was observed in all cases before hospital discharge. During follow-up, all patients were asymptomatic and without residual shunt. There was no deaths or any other complications in the series. CONCLUSIONS: The percutaneous closure of ASD using a Memopart™ device is an effective and safe procedure within the limits of this investigation. The device is user-friendly and has a high rate of immediate occlusion, even in large defects.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Heart Septal Defects, Atrial/physiopathology , Heart Defects, Congenital , Septal Occluder Device , Cardiac Catheterization , Echocardiography, Transesophageal/methods , Prospective Studies , Pulmonary Veins/surgery
20.
Arch. cardiol. Méx ; 83(1): 31-34, ene.-mar. 2013. ilus
Article in Spanish | LILACS | ID: lil-685350

ABSTRACT

El uso del Amplatzer® Vascular Plug (St. Jude Medical-Minnesota, EE. UU.) se ha diversificado y ha sido descrito con éxito en diferentes escenarios clínicos. Se describe otra aplicación para este dispositivo, presentando el caso de una paciente con antecedente de corrección de conexión anómala total de venas pulmonares a quien se le realizó oclusión de una vena vertical permeable con un Amplatzer® Vascular Plug.


The use of the Amplatzer® Vascular Plug has diversified and has been described successfully in different clinical settings. We describe another application for this device, presenting the case of a patient with a history of correction of total anomalous connection of pulmonary veins, who underwent occlusion of the unligated vertical vein with the Amplatzer® Vascular Plug.


Subject(s)
Child, Preschool , Female , Humans , Endovascular Procedures , Pulmonary Veins/abnormalities , Pulmonary Veins/surgery , Septal Occluder Device , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL